ISO 26262ISO 21448ISO/TS 5083ISO/PAS 8800ISO/SAE 21434UN R155/R156AUTOSAR

Specialist Automotive Engineering Consultancy & Solutions

Functional Safety, Safety of the Intended Functionality, Autonomous Driving Safety, Safety and Artificial Intelligence, Cybersecurity & SW Updates and Embedded Software, delivered by one senior expert from concept to assessment.

Send an inquiryExplore services
15+years with OEMs & Tier-1/2
6engineering domains
TÜV SÜDcertified FuSa Professional
4time zones supported

Services

Major work products per domain, ready for assessment, audit and type approval.

Functional Safety

ISO 26262 | ISO/PAS 8926

  • Item definition, HARA, safety goals, FSC & TSC
  • FSR / TSR, HSI, SW / HW requirements
  • FMEA, FTA, DFA and V&V strategy
  • Production & operation, field monitoring
  • Safety plan, safety case, DIA, confirmation reviews
  • Tool, SW / HW and pre-existing SW qualification

Safety of the Intended Functionality

ISO 21448 | ISO 34502 / 34503

  • Safety of the Intended Functionality hazard analysis, acceptance criteria, validation targets
  • Function specification, ODD and known limitations
  • Functional insufficiency & triggering condition analysis
  • Functional modifications to reduce Safety of the Intended Functionality risk
  • Scenario catalogue, coverage and field monitoring
  • Residual-risk argument and Safety of the Intended Functionality safety case

Autonomous Driving Safety

ISO/TS 5083 | UL 4600

  • Safety strategy: ADS feature, ODD, DDT fallback & MRC
  • Risk acceptance criteria and safety requirements
  • Safety by design and requirement allocation
  • Validation metrics and V&V strategy
  • Field monitoring, change & incident management
  • UL 4600 safety case and gap assessment

Safety and Artificial Intelligence

ISO/PAS 8800 | ISO/IEC TR 5469

  • AI system definition and input space
  • Safety and Artificial Intelligence and dataset requirements
  • Monitors, plausibility checks, safe fallback
  • AI hazard and insufficiency analysis
  • Dataset review, AI V&V and operation monitoring
  • Safety and Artificial Intelligence plan and safety case

Cybersecurity & SW Updates

ISO/SAE 21434 | ISO 24089 | UN R155/R156

  • Item definition, TARA, cyber goals and claims
  • Cyber requirements and cyber concept
  • Cyber V&V, pen / fuzz test strategy
  • Vulnerability and incident management
  • CSMS and SUMS setup for UN R155/R156
  • Pre-assessment, type-approval evidence support

Embedded SW & Systems

AUTOSAR | MBSE / SysML | A-SPICE

  • System requirements and HSI (MBSE / SysML)
  • AUTOSAR Classic and Adaptive SW architecture
  • BSW, MCAL and multicore OS integration
  • SW and system V&V strategy and test specs
  • A-SPICE process descriptions and templates

Why SafeSDV?

Why clients choose SafeSDV for real project delivery.

01

Senior-Only Delivery

A certified safety expert works directly with you on every task.

02

Multi-Domain Expertise

FuSa, Safety of the Intended Functionality, ADS, Safety and Artificial Intelligence, Cybersecurity and Embedded SW from one consultant.

03

Proven OEM & Tier-1/2 Delivery

Hands-on delivery for OEMs, Tier-1/2 suppliers and ESPs worldwide.

04

SDV-Ready Engineering

Zonal ECUs, HPC platforms, AUTOSAR Adaptive and OTA safety.

05

Flexible Engagement

Time & Material, Fixed Cost, Milestone-Based or Retainer.

06

Ready-to-Use Work Products

Proven HARA, TARA, safety concept and CSMS gap templates.

07

Support Across Time Zones

Remote and onsite, hours matched to EU, US, Japan and India.

08

Quick Ramp-Up

Productive from week one with standards, tools and work products.

Selected Case Studies

Examples of recent work. Client names are withheld under NDA.

Functional Safety · OEM

Vehicle-Level Safety Concept (ASIL D VCU)

Challenge: New VCU needed safety goals and an FSC.

Approach: Led HARA; wrote safety goals and FSC; derived FSRs.

Outcome: Validation strategy defined per safety goal.

Safety of the Intended Functionality · Tier-1

Safety of the Intended Functionality Gap Analysis & Validation (ACC)

Challenge: ACC needed Safety of the Intended Functionality analysis to ISO 21448.

Approach: Triggering conditions; fusion, fallback and HMI mitigations.

Outcome: Residual risk assessed with scenario-based simulation.

Autonomous Driving Safety · Tier-1

Gap Assessment vs ISO/TS 5083 & UL 4600

Challenge: Existing process missed ADS-specific needs.

Approach: Clause-by-clause review of work products.

Outcome: Prioritised gap report and process templates.

Cybersecurity · Tier-1

Secure OTA Bootloader (AURIX TC387)

Challenge: HEV platform needed fail-safe OTA.

Approach: Dual-bank bootloader with SWAP and rollback.

Outcome: UDS services and flash drivers implemented.

How We Work

A simple path from first conversation to assessment-ready work products.

Scoping call

We discuss your item, standards, phase and deadlines.

Proposal

Clear scope, deliverables and engagement model.

Delivery

Hands-on work with regular reviews in your tools.

Handover

Assessment-ready work products and knowledge transfer.

Who You'll Work With

One senior consultant for the entire scope, with a trusted expert network for larger programmes.

Chaitanya Vikas Kulkarni

Chief Consultant, SafeSDV

Experience
15+ years with leading global OEMs and Tier-1/2 suppliers; 6+ years focused on automotive safety and cybersecurity.
Roles handled
Safety Manager, Safety Engineer, Cybersecurity Manager, Software Architect, Systems Architect, Auditor, Assessor.
Standards applied
ISO 26262ISO 21448ISO/TS 5083ISO/PAS 8800ISO/SAE 21434ISO 24089UN R155/R156AUTOSARA-SPICE
TÜV SÜD Certified
ISO 26262 Functional Safety Professional (Level II)

Also certified in Safety of the Intended Functionality, ISO/SAE 21434 Cybersecurity and Adaptive AUTOSAR.

Engagement Models

Choose the model that suits your project phase, team size and compliance timeline.

Time & Material

Ongoing support, iterative engineering, long programmes.

e.g. safety engineer embedded in your team

Fixed Cost

Defined deliverables with clear entry / exit criteria.

e.g. HARA + FSC for one item; TARA for one ECU

Milestone-Based

Phase-wise delivery linked to type approval or gates.

e.g. safety case built gate by gate up to SOP

Retainer

Regular access to a senior expert without hiring.

e.g. part-time FSM or Cybersecurity Manager

Send an Inquiry

Tell us about your project and we'll get back to you.

Prefer to reach out directly?

Email
chaitanya.kulkarni@safesdv.com

LinkedIn
Chaitanya Vikas Kulkarni

Location
India · Remote worldwide, onsite on request

Working hours
Matched to EU, US, Japan and India